800-645-6733
Check Valves
200 Series Check Valves 0 to 3000 psig
H200 Series High Pressure Check Valves 0 to 6000 psig
2200 Series Check Valves 0 to 800 psig
2300 Series Check Valves 0 to 10000 psig
C200 Series Cartridge Check Valve 0 to 5000 psig
C2900 Series Cartridge Check Valve 0 to 3000 psig
Relief Valves
500 Series Relief Valves 0.5 to 150 psig
HP500 Series Relief Valves 150 to 575 psig
5100 Series Relief Valves 10 to 2400 psig
D500 Series ASME Safety Relief Valves 15 to 150 psig
M5100 Series ASME Relief Valves 20 to 1200 psig
5300 Series Relief Valves 400 to 10500 psig
R6000 Series Right Angle Relief Valves
Solenoid Valves
SV10-SV30 Series Solenoid Valves
SV400 Series Solenoid Valves
Atkomatic Solenoid Valves
15400 Series Solenoid Valves
15800 Series Solenoid Valves
30400 Series Solenoid Valves
30800 Series Solenoid Valves
1000 Series Solenoid Valves
4000/5000 Series Solenoid Valves
6000 Series Solenoid Valves
8000 Series Solenoid Valves
JJ Series Solenoid Valves
HS Series Solenoid Valves
Regulators
Single Stage Pressure Regulators
Cylinder Regulators
Back Pressure Regulators
Hoke Valves
Hoke Needle Valves
Hoke Ball Valves
Hoke Metering Valves
Hoke Check & Relief Valves
Cryogenic Valves & Equip.
Cryogenic Vacuum Jacketed Valves
Cryogenic Non-Jacketed Valves
Filtration
Inline Filters
UHP Fittings
Face Seal Connectors
Face Seal Gaskets, Nuts, Caps & Plugs
Face Seal Unions & Elbows
Face Seal Glands
Mini Weld Fittings
Gyrolok Tube Fittings
Tube to Male Thread
Tube to Female Thread
Tube to Tube Union
Tube to 37° Flare
Tube to Weld
Cap & Plug
Tube Stub Connectors/Adapters
Spare Parts
Specific Applications
Tools & Accessories
Chromatography
Circle Seal Controls Valves
900 Series Shutoff Valve 0 to 6,000 psig
9200 Series Vacuum to 150 psig Plug Shutoff Valves
9300 Series Vacuum to 150 psig Plug Valves 3-way Selector
9400 Series 0 to 3,000 psig Miniature Shutoff Valve
9500 Series 0 to 3,000 psig Shutoff Valve
400 Series Shuttle Valves 0 to 3000 PSI
Precision Pipe Fittings
Pipe Unions
Nipples
Caps and Plugs
Elbows
Tees and Cross
Adapters and Connectors
Search Catalog
By Keyword
By Item #
All Categories
Gyrolok® Dielectric Union
|
Shipping
|
Tax
|
Terms
Shopping Cart
0 Items
Request for Quote
0 Items
All Categories
>
Gyrolok® Tube Fittings
>
Specific Applications
>
Gyrolok® Dielectric Union
>
Item # 4DU-316
Download PDF
Download PDF
Printable Page
Email This Page
Save To Favorites
Please wait…
Item # 4DU-316, Gyrolok® DU Dielectric Union
larger image
For specific applications.
The HOKE Gyrolok Dielectric Tube Fittings are for use in applications where electrical current flowing through a pipe or tube line must be interrupted to protect vital instrumentation and metering equipment.
Unit of Measure:
Imperial
Metric
Both
Specifications
·
Dimensional Data
·
Features & Benefits
·
Technical Data
·
Applications
·
Warning
Specifications
Body Type
Dielectric Union
Fitting Configuration
Specific Applications
Basic Part No.
DU
Body Material
316 Stainless Steel
Connection Size 1
1/4
in
Connection Type 1
Tube Fitting
Connection Size 2
1/4
in
Connection Type 2
Tube Fitting
Type
Tube Fittings
Dimensional Data
Features & Benefits
Thermoplastic Insulators with:
Resistance in excess of 10
8
ohms at 70° F (21 °C) and 50% relative humidity.
Resistance in excess of 10
6
ohms at 100° F (38 °C) and 90% relative humidity.
Maximum safety and protection to critical monitoring station instrumentation.
Metal components made of 316 Stainless Steel
Long component life in rugged environment.
Appropriate orifice for fitting size (e.g. .422” orifice in 1/2” fitting)
Maximum flow capability provided by all sizes of HOKE Gyrolok Dielectric tube fittings.
HOKE Gyrolok tube fitting ends
The unique value and performance offered by HOKE Gyrolok.
Technical Data
Body Construction Materials — 316 Stainless Steel
Insulator — Molded Thermoplastic
O-ring Material — 90 Durometer Viton
Back-up Washer — Virgin TFE
Electrical Resistance of Insulators — 7.0 X 10
8
Ω @ 10 Volts DC @ 70° F and 50% relative humidity. 1.0 X 10
6
Ω @ 10 Volts DC @ 100° F and 90% relative humidity
Pressure Rating — 4000 PSIG @ 70° F (27,580kPa @ 21° C)
Temperature Rating — -40° F to +200° F (-40° C to +93° C)
Design
The Dielectric Tube Fitting must perform three primary functions:
Electrical insulation
Reliable fluid containment
Appropriate flow for line size
In the HOKE design, the insulation function is performed by thermoplastic insulators which provide performance unequaled by any similar product.
A Viton O-ring and TFE back up ring provide the containment function within the fitting. Gyrolok’s 2-ferrule system provides sealing with the impulse line tubing.
Appropriate flow for line size is achieved by providing the appropriate inside diameter for tubing size. See “E” dimensions in Dimensional Table.
Applications
Commonly used in the Natural Gas Transmission industry, the Dielectric Fitting will prevent current flow resulting from Impressed Current Cathodic Protection Systems, static electricity or even lightning strikes, from reaching sensitive monitoring station equipment.
Impressed Current Cathodic Protection Systems involve the application of a low voltage, low amperage direct current to a pipeline and eventual transfer of corrosive effects to a typically underground anode bed.
If the current flow is not interrupted before reaching the monitoring station critical equipment could be damaged or rendered inaccurate.
By installing HOKE’s Gyrolok Dielectric Tube Fitting on impulse lines between the pipeline and the monitoring station, current flow is interrupted while full fluid flow is permitted.
Warning
A “NO WRENCHING” label is placed on the hex of the nut in the insulation sections. Do not disconnect at this point. Instructions are provided with every HOKE Dielectric fitting.
MORE IMAGES
·
Dielectric Unions: DU Dim. Drawing