Thermoplastic Insulators with: Resistance in excess of 108 ohms at 70° F (21 °C) and 50% relative humidity. Resistance in excess of 106 ohms at 100° F (38 °C) and 90% relative humidity.Maximum safety and protection to critical monitoring station instrumentation.
Metal components made of 316 Stainless SteelLong component life in rugged environment.
Appropriate orifice for fitting size (e.g. .422” orifice in 1/2” fitting)Maximum flow capability provided by all sizes of HOKE Gyrolok Dielectric tube fittings.
HOKE Gyrolok tube fitting endsThe unique value and performance offered by HOKE Gyrolok.
|
|
|
|
Body Construction Materials — 316 Stainless Steel Insulator — Molded Thermoplastic O-ring Material — 90 Durometer Viton Back-up Washer — Virgin TFE Electrical Resistance of Insulators — 7.0 X 108 Ω @ 10 Volts DC @ 70° F and 50% relative humidity. 1.0 X 106 Ω @ 10 Volts DC @ 100° F and 90% relative humidity Pressure Rating — 4000 PSIG @ 70° F (27,580kPa @ 21° C) Temperature Rating — -40° F to +200° F (-40° C to +93° C)
Design The Dielectric Tube Fitting must perform three primary functions:- Electrical insulation
- Reliable fluid containment
- Appropriate flow for line size
In the HOKE design, the insulation function is performed by thermoplastic insulators which provide performance unequaled by any similar product.
A Viton O-ring and TFE back up ring provide the containment function within the fitting. Gyrolok’s 2-ferrule system provides sealing with the impulse line tubing.
Appropriate flow for line size is achieved by providing the appropriate inside diameter for tubing size. See “E” dimensions in Dimensional Table.
|
|
|
|

Commonly used in the Natural Gas Transmission industry, the Dielectric Fitting will prevent current flow resulting from Impressed Current Cathodic Protection Systems, static electricity or even lightning strikes, from reaching sensitive monitoring station equipment.
Impressed Current Cathodic Protection Systems involve the application of a low voltage, low amperage direct current to a pipeline and eventual transfer of corrosive effects to a typically underground anode bed.
If the current flow is not interrupted before reaching the monitoring station critical equipment could be damaged or rendered inaccurate.
By installing HOKE’s Gyrolok Dielectric Tube Fitting on impulse lines between the pipeline and the monitoring station, current flow is interrupted while full fluid flow is permitted.
|
|
|
|
A “NO WRENCHING” label is placed on the hex of the nut in the insulation sections. Do not disconnect at this point. Instructions are provided with every HOKE Dielectric fitting.
|
|
|