Print Back
Features
  • Zero leakage up to 95% of cracking pressure
  • No chatter or squeal
  • Positive reseal at a high percentage of cracking pressure
  • No pressure rise with increasing flow
  • Externally adjustable
  • PED certifications and CE marking available for most models
Note:
Proper filtration is recommended to prevent damage to sealing surfaces.
For PED applications, bodies are limited to a maximum temperature use of +100° F (+38° C)
Unit of Measure

Specifications

Series

N/A 5300

Optional Variation

N/A Liquid service, CRES 440C poppet
Body Material1 N/A 303 Stainless Steel

O-Ring Material

N/A Buna N

Valve Size

N/A 1/4 in

End Connections (Inlet/Outlet)

N/A Female NPT

Operating Pressure

N/A 400 to 10500 psig28 to 724 bar

Cracking Pressure

N/A 10 to 10500 psig

Cracking Pressure Tolerance

N/A ±5%

Operating Temperature

N/A -65 to 250 ºF

Special Characteristics

N/A Lockwire (optional)

Optional Body Material

N/A 316 Stainless Steel

Weight

N/A 1.7 lbs

Reseal Pressure and Leakage

N/A Cracking Pressure Tolerance: ±5%

Flow at cracking pressure:

  • Gas = 5cc/min
  • Teflon® seals = 0.02 scfm

    Reseal pressure
    Crack Pressure Reseal Pressures
    400-599 psi 80% of C.P.
    600-899 psi 85% of C.P.
    900-5999 psi 90% of C.P.
    6000 psi & greater 95% of C.P.

    Leakage at reseal pressure

    Gas Ascending pressure = zero to 95% of cracking pressure
      Descending pressure = zero at reseal 
    Liquid Ascending pressure = 5cc/min maximum to 95% of cracking pressure
     

    Descending pressure = 15cc/min maximum at reseal


     

  • Safety

    N/A For Your Safety
    It is solely the responsibility of the system designer and user to select products suitable for their specific application requirements and to ensure proper installation, operation, and maintenance of these products. Material compatibility, product ratings and application details should be considered in the selection. Improper selection or use of products described herein can cause personal injury or property damage.

    • 1 For PED applications, bodies are limeted to a maximum temperature use of +100ºF (+38ºC).